Precision determination for the specific oxygen uptake rate (SOUR) method used for biological stability evaluation of compost and biostabilized products [An article from: Bioresource Technology]
Book Details
PublisherElsevier
ISBN / ASINB000PAU802
ISBN-13978B000PAU804
AvailabilityAvailable for download now
Sales Rank13,221,482
MarketplaceUnited States 🇺🇸
Description
This digital document is a journal article from Bioresource Technology, published by Elsevier in 2007. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.
Description:
This work represents the first attempt to evaluate the precision of the specific oxygen uptake rate method expressed in terms of repeatability (r) and reproducibility limits (R). Three laboratories were involved in an inter-laboratory test for the validation of respiration analyses on six biomass samples (three composts and three biostabilized products) having different degrees of biological stability. Both the maximum specific oxygen uptake rate peak (SOUR) and the cumulative oxygen demand after 12h (OD"1"2) and 20h (OD"2"0) of respiration test were investigated. Precisions expressed as the relative standard deviation were in the range of 9-41%. Linear regressions found for r and R, versus OD"1"2 and OD"2"0, enabled derivation of precision values (r and R) for all respirometric levels within the operating range. The OD"1"2 and OD"2"0 indices were found to be more adequate to indicate biological stability since they were less influenced by random errors than the SOUR index.
Description:
This work represents the first attempt to evaluate the precision of the specific oxygen uptake rate method expressed in terms of repeatability (r) and reproducibility limits (R). Three laboratories were involved in an inter-laboratory test for the validation of respiration analyses on six biomass samples (three composts and three biostabilized products) having different degrees of biological stability. Both the maximum specific oxygen uptake rate peak (SOUR) and the cumulative oxygen demand after 12h (OD"1"2) and 20h (OD"2"0) of respiration test were investigated. Precisions expressed as the relative standard deviation were in the range of 9-41%. Linear regressions found for r and R, versus OD"1"2 and OD"2"0, enabled derivation of precision values (r and R) for all respirometric levels within the operating range. The OD"1"2 and OD"2"0 indices were found to be more adequate to indicate biological stability since they were less influenced by random errors than the SOUR index.