Development of gas chromatography-mass spectrometry following headspace single-drop microextraction and simultaneous derivatization for fast determination ... [An article from: Analytica Chimica Acta]
Book Details
Author(s)L. Dong, X. Shen, C. Deng
PublisherElsevier
ISBN / ASINB000RR8KFI
ISBN-13978B000RR8KF8
AvailabilityAvailable for download now
MarketplaceUnited States 🇺🇸
Description
This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2006. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.
Description:
Acetone in human blood has been regarded as the diabetic biomarker. Acetone analysis is used as the accessorial diagnosis tool for diabetes. In this work, a simple, solvent-free and low-cost technique was developed for fast determination of acetone in blood samples, which was based on headspace single-drop microextraction and simultaneous derivatization followed by gas chromatography-mass spectrometry (GC-MS). Acetone in blood was headspace extracted by using the microdrop solvent containing a derivatization agent of O-(2,3,4,5-pentafluorobenzyl)hydroxylamine (PFBHA). The extracted acetone reacted with PFBHA in the microdrop, and rapidly formed acetone oxime. Finally, the derivative in the microdrop was detected by GC-MS. The parameters of headspace single-drop microextraction and simultaneous derivatization were studied, and the method validations were also studied. The proposed method was tested by the application to the determination of acetone in blood samples from controls and diabetic patients. The results show that headspace single-drop microextraction and simultaneous derivatization followed GC-MS is a simple, rapid, solvent-free and sensitive method for the determination of acetone in blood, and also a potential tool for diagnosis of diabetes.
Description:
Acetone in human blood has been regarded as the diabetic biomarker. Acetone analysis is used as the accessorial diagnosis tool for diabetes. In this work, a simple, solvent-free and low-cost technique was developed for fast determination of acetone in blood samples, which was based on headspace single-drop microextraction and simultaneous derivatization followed by gas chromatography-mass spectrometry (GC-MS). Acetone in blood was headspace extracted by using the microdrop solvent containing a derivatization agent of O-(2,3,4,5-pentafluorobenzyl)hydroxylamine (PFBHA). The extracted acetone reacted with PFBHA in the microdrop, and rapidly formed acetone oxime. Finally, the derivative in the microdrop was detected by GC-MS. The parameters of headspace single-drop microextraction and simultaneous derivatization were studied, and the method validations were also studied. The proposed method was tested by the application to the determination of acetone in blood samples from controls and diabetic patients. The results show that headspace single-drop microextraction and simultaneous derivatization followed GC-MS is a simple, rapid, solvent-free and sensitive method for the determination of acetone in blood, and also a potential tool for diagnosis of diabetes.
