This digital document is an article from ASHRAE Transactions, published by American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. on January 1, 2010. The length of the article is 4677 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available immediately after purchase. You can view it with any web browser.
From the author: This paper presents the experimental as well as the simulated performance studies on the transcritical [CO.sub.2] heat pumps for simultaneous water cooling and heating; effects of water mass flow rates and water inlet temperatures of both evaporator and gas cooler on the cooling and heating capacities, system COP and water outlets temperatures are investigated. Study shows that both the water mass flow rate and inlet temperature have significant effect on system performances. Test results show that the effect of evaporator water mass flow rate on the system performances and water outlet temperatures is more pronounced (COP increases 0.6 for 1 kg/min) compared to the gas cooler water mass flow rate (COP increases 0.4 for 1 kg/min) and the effect of gas cooler water inlet temperature is more significant (COP decreases 0.48 for given ranges) compared to the evaporator water inlet temperature (COP increases 0.43 for given ranges). Comparisons of experimental values with simulated results show the maximum deviation of 5% for cooling capacity, 10% for heating capacity, 16% for system COP. This study offers useful guidelines for selecting appropriate water mass flow rate to obtain required system performance.
Citation Details
Title: Performance of a transcritical [CO.sub.2] heat pump for simultaneous water cooling and heating.(Report)
Author: J. Sarkar
Publication:ASHRAE Transactions (Magazine/Journal)
Date: January 1, 2010
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 116 Issue: 1 Page: 534(8)
Article Type: Report
Distributed by Gale, a part of Cengage Learning
From the author: This paper presents the experimental as well as the simulated performance studies on the transcritical [CO.sub.2] heat pumps for simultaneous water cooling and heating; effects of water mass flow rates and water inlet temperatures of both evaporator and gas cooler on the cooling and heating capacities, system COP and water outlets temperatures are investigated. Study shows that both the water mass flow rate and inlet temperature have significant effect on system performances. Test results show that the effect of evaporator water mass flow rate on the system performances and water outlet temperatures is more pronounced (COP increases 0.6 for 1 kg/min) compared to the gas cooler water mass flow rate (COP increases 0.4 for 1 kg/min) and the effect of gas cooler water inlet temperature is more significant (COP decreases 0.48 for given ranges) compared to the evaporator water inlet temperature (COP increases 0.43 for given ranges). Comparisons of experimental values with simulated results show the maximum deviation of 5% for cooling capacity, 10% for heating capacity, 16% for system COP. This study offers useful guidelines for selecting appropriate water mass flow rate to obtain required system performance.
Citation Details
Title: Performance of a transcritical [CO.sub.2] heat pump for simultaneous water cooling and heating.(Report)
Author: J. Sarkar
Publication:ASHRAE Transactions (Magazine/Journal)
Date: January 1, 2010
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 116 Issue: 1 Page: 534(8)