Simulation of the dynamics of a fire in a one-story restaurant: Texas, February 14, 2000
📄 Viewing lite version
Full site ›
Book Details
Author(s)U.S. Government
PublisherBooks LLC, Reference Series
ISBN / ASIN1234276038
ISBN-139781234276034
AvailabilityUsually ships in 24 hours
MarketplaceUnited States 🇺🇸
Description ▲
Original publisher: Gaithersburg, MD : U.S. Dept. of Commerce, Technology Administration, National Institute of Standards and Technology, [2002] OCLC Number: (OCoLC)55717339 Subject: Fire investigation -- Texas. Excerpt: ... Table 1. Approximate Incident Timeline Approximate Event Simulation Incident Time Time ( s ) ( h:min:s ) 04: 13: 00 Fire started 0 04: 28: 00 Office ceiling collapse 900 04: 30: 00 Fire Department notified of fire by 911 call 1020 04: 33: 00 Fire Department dispatched 1200 04: 38: 00 First Fire Department units arrive 1500 04: 40: 00 West door forced and vented 1620 04: 41: 00 East double doors vents 1680 04: 41: 30 Window next to east side double doors vented 1710 04: 42: 00 Positive pressure fan started at west door 1740 04: 44: 00 Roof and Ceiling collapse 1860 11