Microbial Contamination of Waterline in Dental Units: Bacterial Contamination of Waterline in Dental Clinics by Pseudomonas aeruginosa and Legionella pneuomophila

Author Nivin Al-Alami
Publisher LAP LAMBERT Academic Publishing
📄 Viewing lite version Full site ›
🌎 Shop on Amazon — choose country
64.00 USD
🛒 Buy New on Amazon 🇺🇸 🏷 Buy Used — $75.32

✓ Usually ships in 24 hours

Share:
Book Details
ISBN / ASIN3848419262
ISBN-139783848419265
AvailabilityUsually ships in 24 hours
Sales Rank6,405,608
MarketplaceUnited States 🇺🇸

Description

This is the first study in Jordan to determine the degree of bacterial contamination of water outlets from high-speed drill and air/water syringe waterlines in dental clinics. Total heterotrophic bacterial counts (HPC), in addition to Pseudomonas aeruginosa, and Legionella pneuomophila as opportunistic pathogens were investigated in the source water, high-speed drill and air/water syringe waterlines. Heterotrophic bacterial counts (HPCs) exceeded 500 CFU/ml in 26% of the water sources supplying the units. Pseudomonas aeruginosa was detected in 12% of the source water sample supplying the dental unit in a range of 1-500 CFU/ml. Concentration ranging between 1-100 CFU/ml of Legionella pneuomophila of serogroup 1 was detected in 20% of source water samples. This study has shown that dental unit waterlines were not complying with International Drinking Water standards for heterotrophic mesophilic bacterial count (>500 CFU/ml), nor with the American Dental Association guidelines (>200 CFU/ml). The presence of Pseudomonas aeruginosa and Legionella pneuomophila is an indication of low water quality in dental unit waterlines.