This digital document is an article from ASHRAE Transactions, published by Thomson Gale on July 1, 2007. The length of the article is 8674 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.
From the author: Research into the development of fault detection and diagnosis (FDD) methods as applied to heating, ventilating, air-conditioning, and refrigerating equipment has been ongoing for over a decade, and several papers have been published. However, studies specifically related to large chillers have been few despite the importance of such equipment. The objective of this paper is to propose and illustrate a simple model-based FDD method for medium to large chillers that uses sensors available in most cooling plants, allows tuning of specific thresholds so as to attain the desired compromise between robustness and sensitivity, and has the potential to be automated and implemented online. Lacking actual field data of chillers operated under fault-free and faulty operation, the performance of the proposed FDD method is demonstrated with data generated from tests on a laboratory chiller in the framework of an earlier research study. This proposed FDD scheme is based on five important characteristic features (that have been identified from 15 variables evaluated) that allow six process faults to be identified (although two cannot be done uniquely). Since large chillers are not prepackaged as is unitary equipment, their design and assembly allow selecting different subsystems for a stipulated maximum cooling capacity. In such a case, selection of specific variables needed for FDD will be impacted by different faults, depending on several aspects unique to the chiller installation: the type of chiller load control (thermostatic expansion valve or inlet guide vane), specific choice of the relative heat exchanger size, and the load fraction at which the chiller is usually operated. Hence, it is likely that some customization would be needed to adapt the FDD thresholds and association rules for each chiller installation. Different options and challenges relevant to practical implementation of the proposed FDD method are discussed.
Citation Details
Title: Development and evaluation of a simple model-based automated fault detection and diagnosis (FDD) method suitable for process faults of large chillers.(Technical report)
Author: T. Agami Reddy
Publication:ASHRAE Transactions (Magazine/Journal)
Date: July 1, 2007
Publisher: Thomson Gale
Volume: 113 Issue: 2 Page: 27(13)
Article Type: Technical report
Distributed by Thomson Gale
Development and evaluation of a simple model-based automated fault detection and diagnosis (FDD) method suitable for process faults of large ... report): An article from: ASHRAE Transactions
📄 Viewing lite version
Full site ›
Book Details
Author(s)T. Agami Reddy
PublisherThomson Gale
ISBN / ASINB00122SHIM
ISBN-13978B00122SHI3
AvailabilityAvailable for download now
MarketplaceUnited States 🇺🇸