Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions [An article from: Energy & Buildings]
Book Details
PublisherElsevier
ISBN / ASINB000PDSFCW
ISBN-13978B000PDSFC2
AvailabilityAvailable for download now
Sales Rank6,851,493
MarketplaceUnited States 🇺🇸
Description
This digital document is a journal article from Energy & Buildings, published by Elsevier in 2007. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.
Description:
As a high-efficiency air-conditioning scheme, the variable refrigerant flow (VRF) air-conditioning system is finding its way in office buildings. However, there is no well-known energy simulation software available so far which can be used for the energy analysis of VRF. Based on the generic dynamic building energy simulation environment, EnergyPlus, a new VRF module is developed and the energy usage of the VRF system is investigated. This paper compares the energy consumption of the VRF system with that of two conventional air-conditioning systems, namely, variable air volume (VAV) system as well as fan-coil plus fresh air (FPFA) system. A generic office building is used to accommodate the different types of heating, ventilating, and air-conditioning (HVAC) systems. The work focuses on the energy consumption of the VRF system in the office buildings and helps the designer's evaluation and decision-making on the HVAC systems in the early stages of building design. Simulation results show that the energy-saving potentials of the VRF system are expected to achieve 22.2% and 11.7%, compared with the VAV system and the FPFA system, respectively. Energy-usage breakdown for the end-users in various systems is also presented.
Description:
As a high-efficiency air-conditioning scheme, the variable refrigerant flow (VRF) air-conditioning system is finding its way in office buildings. However, there is no well-known energy simulation software available so far which can be used for the energy analysis of VRF. Based on the generic dynamic building energy simulation environment, EnergyPlus, a new VRF module is developed and the energy usage of the VRF system is investigated. This paper compares the energy consumption of the VRF system with that of two conventional air-conditioning systems, namely, variable air volume (VAV) system as well as fan-coil plus fresh air (FPFA) system. A generic office building is used to accommodate the different types of heating, ventilating, and air-conditioning (HVAC) systems. The work focuses on the energy consumption of the VRF system in the office buildings and helps the designer's evaluation and decision-making on the HVAC systems in the early stages of building design. Simulation results show that the energy-saving potentials of the VRF system are expected to achieve 22.2% and 11.7%, compared with the VAV system and the FPFA system, respectively. Energy-usage breakdown for the end-users in various systems is also presented.