Microbiosensor for acetylcholine and choline based on electropolymerization/sol-gel derived composite membrane [An article from: Analytica Chimica Acta]
Book Details
Author(s)M. Yang, Y. Yang, G. Shen, R. Yu
PublisherElsevier
ISBN / ASINB000RR3GLG
ISBN-13978B000RR3GL3
MarketplaceIndia 🇮🇳
Description
This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2005. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.
Description:
Amperometric enzyme biosensors for the determination of acetylcholine (ACh) and choline (Ch) have been described. For the fabrication of the biosensors, N-acetylaniline (nAN) was first electropolymerized on a Pt electrode surface to be served as a permselective layer to reject interferences. Bovine serum albumin (BSA) and choline oxidase (CHOD) were co-immobilized in a zinc oxide (ZnO) sol-gel membrane on the above modified Pt electrode for a Ch sensor, or CHOD, acetylcholinesterase (AChE) and BSA immobilized together for an ACh/Ch sensor. The poly (N-acetylaniline) (pnAN) film was the first time used for an ACh/Ch sensor and found to have excellent anti-interference ability, and the BSA in the sol-gel can improve the stability and activity of the enzymes. Amperometric detection of ACh and Ch were realized at an applied potential of +0.6V versus SCE. The resulting sensors were characterized by fast response, expanded linear range and low interference from endogenous electroactive species. Temperature and pH dependence and stability of the sensor were investigated. The optimal ACh/Ch sensor gave a linear response range of 1.0x10^-^6 to 1.5x10^-^3M to ACh with a detection limit (S/N=3) of 6.0x10^-^7M and a linear response range up to 1.6x10^-^3M to Ch with a detection limit of 5.0x10^-^7M. The biosensor demonstrated a 95% response within less than 10s.
Description:
Amperometric enzyme biosensors for the determination of acetylcholine (ACh) and choline (Ch) have been described. For the fabrication of the biosensors, N-acetylaniline (nAN) was first electropolymerized on a Pt electrode surface to be served as a permselective layer to reject interferences. Bovine serum albumin (BSA) and choline oxidase (CHOD) were co-immobilized in a zinc oxide (ZnO) sol-gel membrane on the above modified Pt electrode for a Ch sensor, or CHOD, acetylcholinesterase (AChE) and BSA immobilized together for an ACh/Ch sensor. The poly (N-acetylaniline) (pnAN) film was the first time used for an ACh/Ch sensor and found to have excellent anti-interference ability, and the BSA in the sol-gel can improve the stability and activity of the enzymes. Amperometric detection of ACh and Ch were realized at an applied potential of +0.6V versus SCE. The resulting sensors were characterized by fast response, expanded linear range and low interference from endogenous electroactive species. Temperature and pH dependence and stability of the sensor were investigated. The optimal ACh/Ch sensor gave a linear response range of 1.0x10^-^6 to 1.5x10^-^3M to ACh with a detection limit (S/N=3) of 6.0x10^-^7M and a linear response range up to 1.6x10^-^3M to Ch with a detection limit of 5.0x10^-^7M. The biosensor demonstrated a 95% response within less than 10s.
