Heat transfer and pressure drop characteristics of the underfloor air distribution system [An article from: Energy & Buildings]
Book Details
Author(s)M. Zukowski
PublisherElsevier
ISBN / ASINB000RR6NKM
ISBN-13978B000RR6NK4
AvailabilityAvailable for download now
MarketplaceUnited States 🇺🇸
Description
This digital document is a journal article from Energy & Buildings, published by Elsevier in . The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.
Description:
This paper reports experimental data for forced convection heat transfer in a heat exchanger, which is a key part of the underfloor distribution system. The experiments were performed to study heat transfer and pressure drop characteristics of tested units with different geometry of flow ducts. The heat exchanger was made of Plexiglas and PVC. The top side of plastic exchanger was covered by a layer of a concrete screed with thickness of 0.035m. The bottom side was insulated with 0.1m of polystyrene. The length of the tested units was 1m and the width 0.5m. The fluid in the heat exchanger was air. The results of experimental study were presented in a dimensionless form. The average Nusselt number and Fanning friction factor were expressed in terms of the Reynolds number. The experimental results presented in this paper provide useful information for designing of an underfloor air distribution system in the residential housing sector.
Description:
This paper reports experimental data for forced convection heat transfer in a heat exchanger, which is a key part of the underfloor distribution system. The experiments were performed to study heat transfer and pressure drop characteristics of tested units with different geometry of flow ducts. The heat exchanger was made of Plexiglas and PVC. The top side of plastic exchanger was covered by a layer of a concrete screed with thickness of 0.035m. The bottom side was insulated with 0.1m of polystyrene. The length of the tested units was 1m and the width 0.5m. The fluid in the heat exchanger was air. The results of experimental study were presented in a dimensionless form. The average Nusselt number and Fanning friction factor were expressed in terms of the Reynolds number. The experimental results presented in this paper provide useful information for designing of an underfloor air distribution system in the residential housing sector.
![Modeling and designing heating and ventilation system with underfloor air distribution [An article from: Energy & Buildings]](https://www.ebooknetworking.net/books/B00/0RR/medB000RR9ZCK.jpg)
