Low volume sampling device for mass spectrometry analysis of gas formation in nickel-metalhydride (NiMH) batteries [An article from: Analytica Chimica Acta]
Description
This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2006. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.
Description:
Rechargeable nickel-metalhydride (NiMH) batteries have major advantages with respect to environmental friendliness and energy density compared to other battery systems. Research on thermodynamics and reaction kinetics is required to study the behaviour of these batteries, especially under severe operating conditions such as overcharging and (over)discharging. During these processes several reactions take place resulting in the formation of oxygen and hydrogen gas. Hence, the recombination processes should be well controlled to guarantee that the partial oxygen and hydrogen pressure inside the battery are kept low. Mass spectrometry is one of the analytical techniques capable of measuring the composition of gases released inside the battery during the charge and discharge processes. However, the sample gas needs to be withdrawn from the battery during the experiment. The gas consumption must be kept to a minimum otherwise the equilibrium inside the battery will be disturbed. A bench-top quadrupole mass spectrometer with a standard capillary by-pass inlet cannot be used for this purpose as its gas consumption is in the 1-10ml/min range. In this paper, a new gas inlet device is presented that reduces gas consumption to a value
Description:
Rechargeable nickel-metalhydride (NiMH) batteries have major advantages with respect to environmental friendliness and energy density compared to other battery systems. Research on thermodynamics and reaction kinetics is required to study the behaviour of these batteries, especially under severe operating conditions such as overcharging and (over)discharging. During these processes several reactions take place resulting in the formation of oxygen and hydrogen gas. Hence, the recombination processes should be well controlled to guarantee that the partial oxygen and hydrogen pressure inside the battery are kept low. Mass spectrometry is one of the analytical techniques capable of measuring the composition of gases released inside the battery during the charge and discharge processes. However, the sample gas needs to be withdrawn from the battery during the experiment. The gas consumption must be kept to a minimum otherwise the equilibrium inside the battery will be disturbed. A bench-top quadrupole mass spectrometer with a standard capillary by-pass inlet cannot be used for this purpose as its gas consumption is in the 1-10ml/min range. In this paper, a new gas inlet device is presented that reduces gas consumption to a value
