Definition of standard office environments for evaluating the impact of office furniture emissions on indoor VOC concentrations.(volatile organic compound)(Technical ... An article from: ASHRAE Transactions Buy on Amazon

https://www.ebooknetworking.net/books_detail-B00122SHN2.html

Definition of standard office environments for evaluating the impact of office furniture emissions on indoor VOC concentrations.(volatile organic compound)(Technical ... An article from: ASHRAE Transactions

Book Details

PublisherThomson Gale
ISBN / ASINB00122SHN2
ISBN-13978B00122SHN3
MarketplaceFrance  🇫🇷

Description

This digital document is an article from ASHRAE Transactions, published by Thomson Gale on July 1, 2007. The length of the article is 8558 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.

From the author: Based on the analysis, the representative "worst-case" standard open plan office environment for a single workstation system is defined as 5.94 [m.sup.2] (64 [ft.sup.2]) floor area by 2.74 m (9 ft) high (576 [ft.sup.3] or 16.3 [m.sup.3]), accounting for a standard 1.83 m X 1.83 m (6 ft X 6 ft) open plan workstation system, traffic area, and support space for shared copiers, files, storage, etc. The space is assumed to be occupied by a single occupant and has an outdoor or clean air ventilation rate of 4.17 L/s (8.84 cfm), in accordance with ASHRAE Standard 62.1-2004. The representative "worst-case" standard private office environment for a single workstation system is defined as 23.78 [m.sup.2] (256 [ft.sup.2]) floor area by 2.74 m (9 ft) high (2304 f[t.sup.3] or 65.2 [m.sup.3]), accounting for a standard 13.38 [m.sup.2] (144 f[t.sup.2]) private office workstation system, traffic area, and support space for shared copiers, files, storage, etc. The space is assumed to be occupied by a single occupant and has an outdoor or clean air ventilation rate of 9.63 L/s (20.4 cfm) in accordance with ASHRAE Standard 62.1-2004. A comparison to historical office environment models is included.

Citation Details
Title: Definition of standard office environments for evaluating the impact of office furniture emissions on indoor VOC concentrations.(volatile organic compound)(Technical report)
Author: Randal D Carter
Publication:ASHRAE Transactions (Magazine/Journal)
Date: July 1, 2007
Publisher: Thomson Gale
Volume: 113 Issue: 2 Page: 466(12)

Article Type: Technical report

Distributed by Thomson Gale