Transient characteristics of split air-conditioning systems using R-22 and R-410A as refrigerants.(Report): An article from: HVAC & R Research
Book Details
ISBN / ASINB002ED4Q8S
ISBN-13978B002ED4Q84
AvailabilityAvailable for download now
MarketplaceUnited States 🇺🇸
Description
This digital document is an article from HVAC & R Research, published by American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. on May 1, 2009. The length of the article is 10494 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available immediately after purchase. You can view it with any web browser.
From the author: All air-conditioning systems experience transient processes during start-up and shutdown and varying boundary conditions during operation due to changes in space loads and outdoor air loads, control loop operation, etc. Transient characteristics of split air conditioners that use R-22 and R-410A as refrigerants are presented in this paper. The model used for the overall system simulation comprises compressor, capillary, condenser, and evaporator submodels. The condenser and evaporator are modelled using continuity, momentum, and energy equations over the space and time span, using the implicit finite difference approach. Both of the heat exchangers are assumed to be made up of microfin tubes, although a comparison of transient pressure response with smooth tubes is presented in the paper. Appropriate correlations are used for calculating the two-phase heat transfer coefficients, the liquid vapor slip, and the friction factors. A simulation program is developed in the MATLAB (Mathworks 2004) environment linked with REFPROP for refrigerant properties. The program is validated with measured and published experimental data. The transient simulation results including the pressure, the temperature, and the mass flow rate response for a start-up transient are compared for R-22 and its alternative R-410A. The transient loss during start-up due to the reconditioning of thermal mass of the system and redistribution of the refrigerant among the system components is also compared for the two refrigerants.
Citation Details
Title: Transient characteristics of split air-conditioning systems using R-22 and R-410A as refrigerants.(Report)
Author: R.G. Kapadia
Publication:HVAC & R Research (Magazine/Journal)
Date: May 1, 2009
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 15 Issue: 3 Page: 617(33)
Article Type: Report
Distributed by Gale, a part of Cengage Learning
From the author: All air-conditioning systems experience transient processes during start-up and shutdown and varying boundary conditions during operation due to changes in space loads and outdoor air loads, control loop operation, etc. Transient characteristics of split air conditioners that use R-22 and R-410A as refrigerants are presented in this paper. The model used for the overall system simulation comprises compressor, capillary, condenser, and evaporator submodels. The condenser and evaporator are modelled using continuity, momentum, and energy equations over the space and time span, using the implicit finite difference approach. Both of the heat exchangers are assumed to be made up of microfin tubes, although a comparison of transient pressure response with smooth tubes is presented in the paper. Appropriate correlations are used for calculating the two-phase heat transfer coefficients, the liquid vapor slip, and the friction factors. A simulation program is developed in the MATLAB (Mathworks 2004) environment linked with REFPROP for refrigerant properties. The program is validated with measured and published experimental data. The transient simulation results including the pressure, the temperature, and the mass flow rate response for a start-up transient are compared for R-22 and its alternative R-410A. The transient loss during start-up due to the reconditioning of thermal mass of the system and redistribution of the refrigerant among the system components is also compared for the two refrigerants.
Citation Details
Title: Transient characteristics of split air-conditioning systems using R-22 and R-410A as refrigerants.(Report)
Author: R.G. Kapadia
Publication:HVAC & R Research (Magazine/Journal)
Date: May 1, 2009
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 15 Issue: 3 Page: 617(33)
Article Type: Report
Distributed by Gale, a part of Cengage Learning