Enhancing the reliability of chiller control using fused measurement of building cooling load.(Report): An article from: HVAC & R Research
Book Details
ISBN / ASINB002F1RATG
ISBN-13978B002F1RAT9
AvailabilityAvailable for download now
MarketplaceUnited States 🇺🇸
Description
This digital document is an article from HVAC & R Research, published by American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. on November 1, 2008. The length of the article is 7217 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available immediately after purchase. You can view it with any web browser.
From the author: This paper presents a general framework of utilizing a fused measurement of the building instantaneous cooling load to improve the reliability of the chiller sequencing control in building automation systems. The fused measurement is obtained by combining the complementary advantages of two different approaches to measuring the building cooling load. One approach is the direct measurement, which calculates the building cooling load directly, using the differential water temperature and water flow rate measurements. The other is the indirect measurement, which calculates building cooling load based on chiller models using the instantaneous chiller electrical power input, etc. The combination strategy is tested using the field data collected from the central plant of the air-conditioning system in a high-rise building in Hong Kong. The confidence degree associated with the fused measurement is systematically evaluated. Periodic update of the fusion algorithm parameters is also developed to improve the performance of the fusion strategy and the chiller sequencing control.
Citation Details
Title: Enhancing the reliability of chiller control using fused measurement of building cooling load.(Report)
Author: Gongsheng Huang
Publication:HVAC & R Research (Magazine/Journal)
Date: November 1, 2008
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 14 Issue: 6 Page: 941(18)
Article Type: Report
Distributed by Gale, a part of Cengage Learning
From the author: This paper presents a general framework of utilizing a fused measurement of the building instantaneous cooling load to improve the reliability of the chiller sequencing control in building automation systems. The fused measurement is obtained by combining the complementary advantages of two different approaches to measuring the building cooling load. One approach is the direct measurement, which calculates the building cooling load directly, using the differential water temperature and water flow rate measurements. The other is the indirect measurement, which calculates building cooling load based on chiller models using the instantaneous chiller electrical power input, etc. The combination strategy is tested using the field data collected from the central plant of the air-conditioning system in a high-rise building in Hong Kong. The confidence degree associated with the fused measurement is systematically evaluated. Periodic update of the fusion algorithm parameters is also developed to improve the performance of the fusion strategy and the chiller sequencing control.
Citation Details
Title: Enhancing the reliability of chiller control using fused measurement of building cooling load.(Report)
Author: Gongsheng Huang
Publication:HVAC & R Research (Magazine/Journal)
Date: November 1, 2008
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 14 Issue: 6 Page: 941(18)
Article Type: Report
Distributed by Gale, a part of Cengage Learning