Effect of dents in condenser fins on air-conditioner performance.(Report): An article from: ASHRAE Transactions
Book Details
ISBN / ASINB003QN3ZPK
ISBN-13978B003QN3ZP0
AvailabilityAvailable for download now
Sales Rank8,212,387
MarketplaceUnited States 🇺🇸
Description
This digital document is an article from ASHRAE Transactions, published by American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. on January 1, 2010. The length of the article is 3352 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available immediately after purchase. You can view it with any web browser.
From the author: Experiments demonstrated performance degradation in air-conditioning systems resulting from dents in the fins of their condensers and the extent to which conventional fin repair methods restore performance. Two different, commercially available residential-type air-conditioner condensing units were tested. Flattening substantial areas of the fins caused a reduction in capacity and efficiency of the cooling systems tested. Performance dropped appreciably after 60% of the fin areas were pressed flat. With 100% of the fin area flattened, system capacity decreased by 27% and system SEER by 34% for one of the systems. Combing the dented fins after the extreme case where all fins were flattened restored capacity to within 1% and SEER to within 6% of the undented condition. Similar results were obtained for the second condenser unit tested.
Citation Details
Title: Effect of dents in condenser fins on air-conditioner performance.(Report)
Author: Matthew J. Sitzmann
Publication:ASHRAE Transactions (Magazine/Journal)
Date: January 1, 2010
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 116 Issue: 1 Page: 336(10)
Article Type: Report
Distributed by Gale, a part of Cengage Learning
From the author: Experiments demonstrated performance degradation in air-conditioning systems resulting from dents in the fins of their condensers and the extent to which conventional fin repair methods restore performance. Two different, commercially available residential-type air-conditioner condensing units were tested. Flattening substantial areas of the fins caused a reduction in capacity and efficiency of the cooling systems tested. Performance dropped appreciably after 60% of the fin areas were pressed flat. With 100% of the fin area flattened, system capacity decreased by 27% and system SEER by 34% for one of the systems. Combing the dented fins after the extreme case where all fins were flattened restored capacity to within 1% and SEER to within 6% of the undented condition. Similar results were obtained for the second condenser unit tested.
Citation Details
Title: Effect of dents in condenser fins on air-conditioner performance.(Report)
Author: Matthew J. Sitzmann
Publication:ASHRAE Transactions (Magazine/Journal)
Date: January 1, 2010
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 116 Issue: 1 Page: 336(10)
Article Type: Report
Distributed by Gale, a part of Cengage Learning