Exergy aspects of operative temperature and its implications on sustainable building performance.(Report): An article from: ASHRAE Transactions Buy on Amazon

https://www.ebooknetworking.net/books_detail-B004S4QLP2.html

Exergy aspects of operative temperature and its implications on sustainable building performance.(Report): An article from: ASHRAE Transactions

Book Details

Author(s)Birol Kilkis
ISBN / ASINB004S4QLP2
ISBN-13978B004S4QLP4
MarketplaceCanada  🇨🇦

Description

This digital document is an article from ASHRAE Transactions, published by American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. on July 1, 2010. The length of the article is 3724 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available immediately after purchase. You can view it with any web browser.

From the author: Indoor thermal comfort depends on the operative temperature, which is a function of the dry-bulb air temperature and the mean radiant temperature. For maximum comfort, an optimum combination of these temperatures is necessary, because each of them independently affects the heat losses (gains) and thus the energy and exergy demand of the building. Therefore, especially in high-performing sustainable buildings both temperatures need to be separately and optimally controlled for higher energy and exergy efficiencies. Another optimality condition arises due to the exergy loss from the human body, which needs to be minimized. Consequently, air exergy, radiant exergy of the enclosing surfaces, and human body exergy loss become dominant factors for finding the right balance between the comfort and efficiency of a building. The problem becomes more complex when the latent cooling loads are also considered. This study establishes a fundamental relationship among thermal comfort, exergetic comfort, energy, and exergy efficiency and introduces a new optimization algorithm. Results show that calculation of air exergy and radiant exergy is an important step to determine the optimum split of air temperature (dry-bulb) and mean radiant temperature, while minimum human body exergy loss provides the most comprehensive condition for the operative temperature. Sample calculations based on Rational Exergy Management Model (REMM) show that substantial energy savings may be achieved with minimum carbon footprint while human exergy loss is optimized for better comfort during heating and cooling seasons.

Citation Details
Title: Exergy aspects of operative temperature and its implications on sustainable building performance.(Report)
Author: Birol Kilkis
Publication:ASHRAE Transactions (Magazine/Journal)
Date: July 1, 2010
Publisher: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
Volume: 116 Issue: 2 Page: 98(10)

Article Type: Report

Distributed by Gale, a part of Cengage Learning
Donate to EbookNetworking
Prev
Next